Maritime Propulsion Marine engines, propulsors, electrification and drivetrain news

Crowcon Remote / Digital Service

data centres

From grain milling to refrigeration, the food and beverage industry encounters distinct gas hazards. Crowcon’s gas monitoring systems are essential for protecting your workforce, ensuring safety throughout various stages of production and processing.

Description

data centres

Data centres are being built faster than any other class of critical infrastructure. The systems that make them reliable are the same systems that introduce gas risk: battery backup, mechanical cooling, standby generation, electrical distribution and gaseous suppression.

These are sealed, low-occupancy buildings engineered to keep air exactly where it is put, which is precisely what makes a leak dangerous. From UPS halls to chiller plant, Crowcon’s fixed and portable detection protects the people who open these rooms and the continuity of the service behind them.

view the range CONTACT US

GAS HAZARDS IN DATA CENTRES

Detection designed for a whole building protects none of it properly. Each space in a data centre has its own gas, its own accumulation behaviour and its own correct mounting height.

UPS and battery rooms

Primary gases: H₂, lithium-ion off-gas (DMC, EMC, VOCs), CO, HF

Lead-acid and NiCd batteries on charge release hydrogen (H₂) continuously, and hydrogen is explosive from 4% by volume in rooms full of switchgear, busbars and DC connections. A lithium-ion cell driven into thermal runaway vents electrolyte carbonates, carbon monoxide (CO) and hydrogen fluoride (HF) within minutes. Most published incidents happened during replacement or relocation work, when ventilation was isolated but gassing continued. Hydrogen rises, so detection belongs at or near ceiling level, above the banks and away from supply air, interlocked to extract.

BESS & energy storage

Primary gases: lithium-ion off-gas, H₂, CO, HF

Co-located battery energy storage brings utility-scale lithium-ion inside the fence line. A stressed cell vents dimethyl carbonate and other electrolyte vapours before there is any smoke, heat or flame, followed by hydrogen (H₂), carbon monoxide (CO) and hydrogen fluoride (HF) as it fails. Off-gas detection is therefore the earliest warning of thermal runaway available. The 2026 edition of NFPA 855 no longer accepts passive venting alone, expecting detection interlocked to exhaust and concentration held below 25% LFL, with the alarm routed to a manned position.

Chiller & mechanical plant

Primary gases: refrigerants (R410A, R32, R454B, R134a, R-1234ze), CO₂, NH₃, propane, O₂ depletion

Mechanical plant holds the largest gas inventory on most sites: refrigerant charges of R410A, R32, R454B, R134a, R-1234ze, CO₂ or propane spread across chillers, compressors, condensers and pipework, with hundreds of joints and fittings. Most are heavier than air, so a leak sinks into plant rooms, pits and plenums, displacing oxygen (O₂) and taking cooling capacity with it. Newer blends add mild flammability, and industrial chillers may hold ammonia (NH₃), toxic and corrosive, whose smell stops warning anyone within minutes. Detection sits low, near compressors and likely leak points, with the readout outside the room.

Generator halls & fuel storage

Primary gases: CO, NO₂, fuel vapour

Standby generators produce carbon monoxide (CO) and nitrogen dioxide (NO₂) whenever they run, and load bank or black start testing runs them deliberately, at length, usually when fewest people are on site. Both are dangerous at low concentration: EH40 sets 20 ppm for CO over eight hours and just 0.5 ppm for NO₂. Enclosed halls restrict dispersion, and exhaust has repeatedly re-entered buildings through air intakes. Adjacent bulk fuel adds flammable vapour. Detection belongs at breathing height near the units, exhaust routes and intakes, with flame detection covering the fuel yard.

Data halls & underfloor voids

Primary gases: refrigerants, coolant vapour, CO₂, O₂ depletion

Cooling now sits in the same volume as the compute. In-row coolers, CRAC and CRAH units, coolant distribution units and liquid cooling pipework put refrigerant and coolant vapour alongside the racks, and liquid cooling passed half of all new high-performance deployments in early 2026. Every make and break of a coupling is a release point. Refrigerants and CO₂ are dense, so raised floors, plenums and cable voids become accumulation points where oxygen (O₂) can be displaced. Detection sits low, positioned by containment and airflow rather than a drawing grid.

Switch rooms & suppression zones

Primary gases: SF₆, CO₂, O₂ depletion

High-voltage switchgear insulated with sulphur hexafluoride (SF₆) can leak steadily or fail suddenly. SF₆ is an asphyxiant that produces toxic decomposition products after arcing, and being extremely dense it settles into basements, cable pits and trenches; one cracked flange at a substation released 33.92 kg. Suppression systems and cylinder stores hold carbon dioxide (CO₂) or inert gas at design concentrations far above any safe exposure level, so CO₂ and oxygen (O₂) monitoring is what confirms a room is safe to re-enter. Detect at floor level in pits, and at working height in gas stores.

Water treatment & chemical dosing

Primary gases: Cl₂, water treatment chemicals

Cooling water systems bring chlorine (Cl₂), dosing chemicals and cleaning agents onto site, in plant areas rarely considered part of the gas safety case. Chlorine causes severe respiratory injury and is heavier than air, spreading at low level. At a large data centre in Maiden, North Carolina, a spill of a chemical used to clean the cooling system released chlorine and sent five workers to hospital with dizziness and respiratory symptoms. Fixed detection mounted low in dosing rooms and chemical stores matters here, because these spaces are usually unoccupied and often entered alone.

ten gases. one building

Battery backup, mechanical cooling, standby generation, switchgear and suppression put ten different gases in one data centre, seven of them heavier than air, in rooms engineered to keep air exactly where you put it. This guide sets out where those hazards sit, what the global incident record has taught the industry, how the rules differ by region, and what a proportionate detection strategy looks like.

DOWNLOAD THE GUIDE

Gas detectors for DATA CENTRES

Portable Gas Detection

UNOIQ

A personal, rechargeable and modular single-gas detector with extended battery life, modular sensors, and seamless connectivity for enhanced safety.

GAS-PRO

A rugged, portable multi-gas detector with a pre-entry check mode, providing compact detection of up to 5 gases

T4x

Versatile and easy to use, the T4x comes with long-life O₂ and MPS™ sensor technologies for enhanced general protection

DETECTIVEIQ

Configurable area monitor for temporary worksites, a rugged multi-gas detector with industry leading battery life, modular sensors, and seamless connectivity…

Fixed Gas Detection

XGARD BRIGHT

The easy-to-operate flameproof fixed detector provides flammable and toxic gas detection and oxygen monitoring, with reduced installation costs

BESAFE

BESafe is a state-of-the-art dual-channel gas detector with smart sensors, built for battery energy storage systems. It offers fast response,…

SMART 3-R

Fixed detector designed for machinery rooms, laboratories and non-classified areas to detect flammable, toxic and refrigerant gasses in non-hazardous environments.

XGARDIQ

Our most intelligent fixed gas detector, the XgardIQ minimises the time operators must spend in hazardous areas, improving safety.

SMART 3G-D2

A fixed detector with display, capable of detecting over 50 gases. Perfect for harsh environments across a range of industries

SMART 3 BLIZZARD

Flame Detection

FGARD IR3

This multi-spectrum infrared (IR) flame detector delivers superior performance, responding to hydrocarbon liquid fuel and gas fires at long distances.

FGARD H2

Delivers first-in-class hydrogen flame detection with intelligent heated optics for clearer results and advanced optical verification to greatly reduce false…

Control Panels

GASMASTER

With an extendable modular design, this control panel can monitor up to four detectors in virtually any combination

VORTEX

However complex

More from Crowcon

All services of Crowcon →

Similar services